If the malfunction still exists 4 minutes after the device stops due to compressor protection, the error code will be directly displayed on the display of the indoor unit. In other cases, an error code may be displayed by pressing the LIGHT button 6 times in 4 seconds.
Codes |
Indication |
Malfunction |
Possible reasons |
E2 |
RUN indicator off for 3s and blinks 2 times |
Inner spiral defrost protection |
|
E4 |
RUN indicator off for 3s and blinks 4 times |
Compressor overheat protection |
|
E5 |
RUN indicator off for 3s and blinks 5 times |
Overvoltage Protection |
|
E6 |
RUN indicator off for 3s and blinks 6 times |
Communication failure |
|
HER |
HEAT indicator off for 3s and blinks 15 times |
EEPROM error (memory chip) |
Replace indoor unit board |
F0 |
COOL indicator off for 3s and blinks 10 times |
Lack of Freon or Block Protection |
|
F1 |
COOL indicator off for 3s and blinks 1 time |
Malfunction INTERNAL AIR TEMPERATURE SENSOR |
|
F2 |
COOL indicator off for 3s and blinks 2 times |
Malfunction of the INTERNAL TEMPERATURE SPIRAL sensor (RT2) |
F3 |
COOL indicator off for 3s and blinks 3 times |
Outside sensor sensor malfunction temperature |
|
F4 |
COOL indicator off for 3s and blinks 4 times |
Malfunction of the outdoor temperature sensor |
|
F5 |
COOL indicator off for 3s and blinks 5 times |
Compressor temperature sensor malfunction |
|
H3 |
HEAT indicator off for 3s and blinks 3 times |
Compressor overload protection |
|
H4 |
HEAT indicator off for 3s and blinks 4 times |
System overload |
The system is unstable, check that the evaporator and condenser are dirty and blocked. |
H6 |
HEAT indicator off for 3s and blinks 6 times |
no feedback from indoor unit motor |
|
H7 |
HEAT indicator off for 3s and blinks 7 times |
Sync failure |
|
|
HEAT indicator off for 3s and blinks 11 times |
Air conditioner start failure |
|
P7 |
HEAT indicator off for 3s and blinks 18 times |
Radiator temperature sensor malfunction |
|
P8 |
HEAT indicator off for 3s and blinks 19 times |
Radiator temperature sensor overheat protection |
|
PH |
COOL indicator off for 3s and blinks 11 times |
High voltage |
|
PL |
HEAT indicator off for 3s and blinks 21 times |
Low voltage |
|
U1 |
HEAT indicator off for 3s and blinks 13 times |
Compressor phase failure |
Replace outdoor main board Replace the outdoor unit board |
U5 |
COOL indicator off for 3s and blinks 13 times |
AC problem detected |
Replace the outdoor unit board |
U7 |
COOL indicator off for 3s and blinks 20 times |
Check Valve Malfunction |
|
UA |
The HEAD and COOL indicators flash 12 times simultaneously |
Configuration errors |
The indoor unit does not match the outdoor unit |
UF |
The HEAD and COOL indicators blink 7 times simultaneously |
Zero transition protection (indoor unit) |
Replace indoor unit board |
UH |
The HEAD and COOL indicators blink 8 times simultaneously |
There is no feedback from the motor of the external unit |
Can this malfunction occur when an indoor unit motor is used? |
UU |
HEAD and COOL indicators blink 11 times simultaneously |
DC over current High voltage |
|
vangelis (Wednesday, 14 February 2024 07:40)
I found an error f28
Tesha (Friday, 22 September 2023 10:45)
Error code E1 means
Thulani (Saturday, 18 March 2023 07:48)
Error code E1
Keith (Thursday, 16 March 2023 17:55)
Where is E20?
Joe farrugia (Friday, 10 February 2023 18:45)
Can somebody explain the fault code E3 on a 24 btu airwell tks
محمد (Thursday, 02 February 2023 20:00)
error ee
Joseph Schembri (Thursday, 13 October 2022 06:21)
What does F on display means?
Joseph (Monday, 15 August 2022 21:51)
What Is the meaning of PO display on 1200btu air condition. It is not working on cooling. Blower working good on all modes.
Thank you.
john frendo (Monday, 04 July 2022 18:27)
hi i have airwell and ihave errore HC can u tell me the problem
MarkPiccinino (Monday, 27 June 2022 10:21)
What's the error code P3 pls?
Christopher Camilleri (Thursday, 23 June 2022 06:56)
What does P1 mean?
andrew.scicluna@um.edu.mt (Friday, 09 July 2021 09:22)
Hi , we have a split unit installed recently Biology dept Malta , and is not cooling .
the unit is displaying PC 00 when switched on.
Is it possible to have feedback what could be the problem.
Thanks appreciate any feedback since this is the second time it went faulty in a less than two months installed.
ihssan (Thursday, 25 March 2021 11:02)
i have problem with
Airwell cassette ceiling split air conditioner
the error code f7 what is it mean
Jacob (Saturday, 23 January 2021 16:00)
My Ac is showing 26.0