Title |
File Size |
Download Links |
ACRC installation Manual.pdf |
1.6Mb |
|
APC ACPA4000 Air Conditioner Installation, Operation, fnd Maintenance.pdf |
1.1Mb |
|
APC ACPCW40-150 Air Conditioner User Manual .pdf |
923.9kb |
|
APC ACPDX21-86 Air Conditioner User Manual .pdf |
923.9kb |
|
APC ACPSC2000 Air Conditioner User Manual.pdf |
1.3Mb |
|
APC ACPSC3000 Air Conditioner User Guide .pdf |
1.3Mb |
|
APC ACPSC3500 Air Conditioner User Manual.pdf |
1.3Mb |
APC AP7003 Air Conditioner User's Manual.pdf |
702.8kb |
|
APC AP7004 Air Conditioner User's Manual.pdf |
702.8kb |
|
APC Catalog.pdf |
4.7Mb |
|
APC InRowRD ACRD100/ 101 Installation Manual.pdf |
1.5Mb |
|
APC Schematic Diagram.pdf |
175.1kb |
|
InRow AC RP Technical Data.pdf |
2.2Mb |
|
InRow installation Manual.pdf |
2.8Mb |
|
InRow RC Technical Data.pdf |
2.5Mb |
|
InRow User & Maintenance Manual.pdf |
1.3Mb |
APC is one of the most expensive and prestigious brands in the market for precision HVAC equipment. Their model range is based on the principles of "close proximity" of heat-generating equipment and equipment for absorbing heat surpluses. These are, as a rule, in-line models based on water and air cooling. The uniqueness of APC products lies in the fact that they produce products that are not typical of their industry, but most importantly, that these products are an example of quality, manufacturability and reliability. Consider the APC lineup.
Portable Cooling - mobile air conditioners - compact portable solutions for local temperature control in small rooms with a total cooling capacity of up to 3.5 kW.
InRow RA, 300mm, Pumped Refrigerant, 200-240V, 50 / 60Hz - Extremely close to heat sources cooling system with active refrigerant circulation for medium and large data centers. They are used together with KKB as indoor units and also as closers when using freons with low condensing pressures as a recirculating coolant.
InRow chiller water - the water cooling system extremely close to heat sources for medium and large data centers (up to 70 kW).
The InRow Water-Cooled (CW) unit is designed to closely approximate the cooling system and the heat-generating IT load. This design prevents the recirculation of hot air, while improving the predictability of cooling and realizing the principle of payment as it grows. Offered in versions with and without humidity control, these products are designed to meet the diverse needs of medium and large data centers. Data center operators seeking to increase efficiency or deploy high energy density servers will appreciate the benefits of the modular design of InRow water-cooled systems. InRow CW's automated product controls actively adjust fan speeds and chilled water flow based on the actual heat load of IT systems to maximize efficiency and meet the dynamic needs of today's IT environments.
InRow direct expansion - precision in-line air conditioners with air supply frontally to a cold corridor or directly to a closed rack. By the type of condenser cooling, monoblock-type models are produced with the removal of warm air into the ceiling space by means of a flexible duct, with remote condensers and with a water-cooled condenser.
Joseph Gorman (Wednesday, 20 October 2021 17:38)
Did APC acquire Airflow Company? If so, I'm trying to obtain O&M and parts info for a Model CCT-25C4-D CRAC.